Technical Data |
MODEL |
LVM3000-48PL |
Capacity |
3KVA/3KW |
Parallel Capability |
YES,12 Units |
Split phase operation |
YES,need at least 2 units parallel |
INPUT |
|
Nominal Voltage |
110/120VAC |
Acceptable Voltage Range |
95-140VAC(For personal Computer);65-140VAC(For Home Appliances) |
Frequency |
50/60 Hz(Auto sensing) |
OUTPUT |
|
Nominal Voltage |
110/120VAC±5% |
Surge Power |
6000VA |
Frequency |
50/60Hz |
Waveform |
Pure Sine wave |
Transfer Time |
10ms(For personal Computer);20ms(For Home Appliances) |
Peak Efficiency(PV to INV) |
97% |
Peak Efficiency(Battery to INV) |
93% |
Overload Protection |
5s@>=150%load;10s@110%~150%load |
Crest Factor |
3:1 |
Admissible Power Facto |
0.6~1(inductive or capacitive) |
BATTERY |
|
Battery Voltage |
48VDC |
Floating Charge Voltage |
54VDC |
OverCharge Protection |
63VDC |
Charging Method |
CC/CV |
Solar Charger &AC Charger |
|
Max.PV Array Power |
5000W |
Solar Charger Type |
MPPT |
Max.PV Array Open Circuit Voltage |
500VDC |
PV Array MPPT Voltage Range |
120VDC~450VDC |
Max Solar Input Current |
18A |
Max.Solar Charge Current |
80A |
Max.AC Charge Current |
60A |
Max.Charge Current |
80A |
PHYSICAL |
|
Dimensions,DxWxH(mm) |
448x315x122 |
Package Dimensions,Dx Wx H(mm) |
540x390x217 |
Net Weight(Kg) |
10 |
Communication Interface |
RS485/RS232/Dry-contact |
ENVIRONMENT |
|
Operating Temperature Range |
(-10℃ ~ 50℃) |
Storage Temperature |
(-15℃ ~ 50℃) |
Humidity |
5% to 95% Relative Humidity(Non-condensing) |
Product specifications are subject to change without further notice. |